Gold Member Since 2011
Audited Supplier
Biobase Biodustry (Shandong) Co., Ltd.

Spectrophotometer, UV/Vis Spectrophotometer, Lab Furniture manufacturer / supplier in China, offering Double Beam Spectrophotometer Used on Ventilation Lab Hood/Exhaust System Furniture, Biobase LED Neonatal Jaundice Phototherapy Device, Biobase High Power LED Neonatal Jaundice Phototherapy Device and so on.

(/ )

Supplier Homepage Product More Laboratory Equipment Others More Laboratory Equipment Double Beam Spectrophotometer Used on Ventilation Lab Hood/Exhaust System Furniture

Double Beam Spectrophotometer Used on Ventilation Lab Hood/Exhaust System Furniture

Purchase Qty.:
(Pieces)
1-349 350+
FOB Unit Price: US $1,400 US $4,000
Purchase Qty. (Pieces) FOB Unit Price
1-349 US $1,400
350+ US $4,000
Get Latest Price
Production Capacity: 1000sets Per Months
Transport Package: Carton
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: spectrophotometer
  • Warranty: > 1Year
  • Advantage: High Sensitive
  • Wavelengths: Visible Spectrometer
  • Light Number: Monochromator
  • Customized: Non-Customized
  • Wavelength Range: 190-1100nm
  • Wavelength Accuracy: 0.3nm
  • Stray Light: ≤ 0.1 % T @ 360nm; 220nm(0.2)
  • Photometric Mode: T, a, C, E
  • Output: USB2.0*2 Print and Data Output USB1.0 Connect PC
  • Specification: ISO, CE
  • HS Code: 902730000
  • Application: Laboratory Apparatus
  • Detection Method: Spectrophotometer
  • Principle: Classic Spectrometer
  • Dispersive Element: Grating Spectrometer
  • Certification: ISO9001, CE
  • Optical System: Double Beam, Grating 1200 Lines/mm
  • Spectral Bandwidth: 4nm
  • Wavelength Repeatability: 0.2nm
  • Display: 128*64 Dots LCD
  • Photometric Range: 0-200%T, -0.301-3.0A
  • Trademark: BIOBASE
  • Origin: China
Product Description
Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with CE certification

Double Beam Spectrophotometer Used on Ventilation Lab Hood/Exhaust System Furniture
Application

Spectrophotometers are widely used for Organic chemistry,
Inorganic chemistry,Life sciences,foods, Medicine and health,
Agriculture,Geology,Metallurgy and Environment etc.fields.



Features:
Large LCD screen(480*800) with 65 thousand true color and support U disk data saving
Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
 Data output: Data can be exported to U disk (USB Output)
Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
 Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
Pre-aligned design ensures the user can change lamps conveniently
With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off protection
Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
With Si02 coating optical mirror, reducing the pollution from outside fully
 
Basic Functions:
 1, Photometry
  Test Abs., Transmittance and Energy by fixed
  wavelength 
2, Quantitative
   Linear fit and Linear fit through zero two modes
 a.Coefficient, Standard Sample input and Standard
 Sample read three modes to establish standard curve    
 b. Establish A=K1*C+K0, can search original data, graph
   curve, parameters settings  
 c. Can save 240 group curves, can test 240 data in each
  curve 
 d. Double wavelength, Triple wavelength test functions.
3, Kinetics
Used for time course scanning or reaction rate
calculationsA/t, can search all data 
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different
wavelengths at most
5, Scanning
   User can set the scan range from 190nm to 
   1100nm to test the max. Abs. peak value, can do 
   derivation, arithmetical operations to the graph.
6, Biology
   6 methods: DNA/Protein, UV, Lowry, BCA,CBB 
   and Biuret

Parameters
 

Model

BK-D560

BK-D580

BK-D590

Optical System

Double Beam, Grating 1200 lines/mm

Wavelength Range

190-1100nm

Wavelength Range

1.8nm

1nm

0.5,1,2,4,5nm

Wavelength Accuracy

± 0.3nm

Wavelength Repeatability

≤ 0.2nm

Photometric Accuracy

± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.3% T (0-100% T) (0.3, 0.003)

Photometric Repeatability

0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs), ≤ 0.2% T (0-100% T)

Stray Light

≤ 0.03 T @ 360nm; 220nm(0.04)

Stability

± 0.0003A / h @ 500nm

Baseline Flatness

± 0.0005A

Noise

± 0.0002Abs

Display

65 thousand true color 7 inch TFT LCD(480 *800)

Photometric Mode

T, A, C, E

Photometric Range

0-200% T,-0.301-3.0A

Detector

Silicon Photodiode

Light Source

Deuterium Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

USB2.0*2 Print and data output  USB1.0 Connect PC

Compartment

Optional 8 Auto Cell holder, Solid Sample Holder, Micro Cell Holder, 10-100mm Cell Holder

Biobase Advantage:
1.Established in 1999,owning more than 1300 employees & 20000 square meters production base and 22.4 acres industry park, amount to 10000 units yearly output.
2.16 years production experience &100 professional engineers.
3.Third party strong quality control team and technical production.
4.Certified by NSF49, EN12469, CE, ISO13485, ISO14001, ISO9001, SFDA,TUV, SGS, FDA, MET.
5.Superior quality & competitive price are guaranteed.
6.At least 10 international affairs attend yearly: American FIME&Pittcon,AACC exhibition,Russia Zdravook hraneniye, Arab health&Lab, Germany Analytica&Media,Brazil Hospitalar,India Lab expo&Medical fair,Lab Indonesia, Medical Myanmar,Analytica Vietnam,Lab Asia,etc.

BIOBASE is your best choice!
Product Groups
Send your message to this supplier
Avatar
Ms. Candy Wang
*From:
To: Ms. Candy Wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now