• Biobase Bk-AA4530f Auto Absorption Spectrophotometer
  • Biobase Bk-AA4530f Auto Absorption Spectrophotometer
  • Biobase Bk-AA4530f Auto Absorption Spectrophotometer
  • Biobase Bk-AA4530f Auto Absorption Spectrophotometer
  • Biobase Bk-AA4530f Auto Absorption Spectrophotometer
  • Biobase Bk-AA4530f Auto Absorption Spectrophotometer

Biobase Bk-AA4530f Auto Absorption Spectrophotometer

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Shandong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)

Basic Info.

Model NO.
BK-AA4530F
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001
Customized
Non-Customized
Transport Package
by Carton
Specification
850 x 700 x 750mm, 950 x 620 x 1020mm
Trademark
BIOBASE
Origin
China
Production Capacity
500PCS / Month

Product Description

Biobase Bk-AA4530f Auto Absorption Spectrophotometer
BK-AA4530F Atomic Absorption Spectrophotometer

Features:
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design improves the optical system shock resistance stable. 
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as
optimize the working condition of the hollow cathode lamp.
4.Position adjusting: the flame burner can be set on the best position automatically.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: warning and automatic safety protection for the wrong
    burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
7. self-absorption background calibration.
8.Measuring method: flame absorption method and emission method.
9.Result printing: parameter, data result and diagram.
10. Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
 
 
Technical Parameters:
Model BK-AA4530F
Wavelength Range 190 - 900nm
Wavelength Accuracy ±0.15nm
Wavelength Receptivity ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Concentration  0.02μg/ml/1% (Cu)
Detection Limit 0.004μg/ml (Cu)
Measurement Repeatability ≤0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Efficient glass atomizer
Lamp stand 8
D2 background Calibration When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power Supply 220V, 50/60Hz
Packing Size(mm) 850 x 700 x 750(Main instrument)
950 x 620 x 1020( Accessories )
Gross Weight(kg) 105Kg  (Main instrument)
100Kg   ( Accessories )
Standard Accessories PC workstation
HP inkjet printer 
Oil free Air compressor
Acetylene reducing valve
Cu Hollow cathode lamp
Air filter
Optional Accessories Graphite Furnace
Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)
 
 
FLAME SYSTEM
Acetylene Air Burner 100mm
Ignition Dynamic Baseline Drift ≤0.006A/30min
Characteristic Concentration ≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy
 
≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.
 
GRAPHITE FURNACE(Optional):
Max. temperature 3000ºC
Max Heating Speed ≥2000ºC/S
Characteristic Quantity Cd≤0.5×10-12g  Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Safety system Over current protection Low air pressure alarm / protection
Low cooling water flow alarm/protection
Power Supply 220V, 50Hz /60Hz 
Consumption 7000W
Packing Size(mm) 550*450*300
Gross Weight(kg) 65

Company Information
 
BIOBASE group, founded in 1999 and been through high and stable development for 17 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.

The products we manufacture extends to most of the laboratory items and scientific analytical equipments. Our mission is to enable our customers to make the world healthier, cleaner and safer.

BIOBASE group invests in science and technology research, aim to keep impoving products performance and quality as well as develop new products to meet customers wide requirement.
We satisfy our customers by offering comprehensive support, purchase convenience and we are ready to serves more and more BIOBASE users.

BIOBASE group, serving global distributors and its loyal end users, is becoming one of the most important scientific services supplier.

We have branch office in USA, India and Jordan .
Till now we have exported to more than 200 countries.
Biobase Bk-AA4530f Auto Absorption Spectrophotometer
Biobase Bk-AA4530f Auto Absorption Spectrophotometer
Biobase Bk-AA4530f Auto Absorption Spectrophotometer

You can also known more about our company information by visiting our social network.
Facebook: https://biobase.en.made-in-china.com/ 

Twitter : https://biobase.en.made-in-china.com 


Contact Me

Biobase Bk-AA4530f Auto Absorption Spectrophotometer

we will be your best choice!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now