Medical Devices Reg./Record No.: | Lsyjxzz-2014-2400384 |
---|---|
Certificaticate: | CE, FDA, ISO9001, ISO14001, ISO13485 |
Throughput: | 400t/H |
Analysis Method: | End-Point, Fixed-Time,Rate |
Sample Volume: | 2UL ~50UL |
Sample Probe: | Having Liquid Level Induction Function |
Customization: |
---|
Suppliers with verified business licenses
Overall Performance |
Model | BIOBASE-DIAMOND | ||||
Type | discrete, fully automatic | |||||
Throughput | 400 T/H | |||||
Analysis Method | End-point, Fixed-time,Rate | |||||
Programming Items | programmable for any test items | |||||
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |||||
Sample unit |
Sample Settings | 60/90 sample positions, including calibration, quality control and emergency. | ||||
Sample Volume | 2ul ~50ul (0.1ul stepping) | |||||
Sample Probe | Having liquid level induction function. | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Analysis Items | analyzing maximally 45 items at the same time | |||||
Reagent unit |
Reagent Position | R1:45 R2:45 total 90 refrigerated reagent position | ||||
Reagent Volume | R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different brand | |||||
Temperature Control | continuous 2C~8Ccooling within 24 hours | |||||
Reagent Probe | Having liquid level induction fsunction | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Reaction unit | Reaction Time | 10 minutes | Temperature | 37C±0.1C | ||
Cuvettes | 120 reaction cuvettes (optical path length 6mm) | |||||
Mixer | after injecting reagent and sample, blending immediately | |||||
Cleaning | automatic water cleaning and drying system | |||||
System Adjustment | System record the blank value and get more accurate result by deducting blank base value of each cuvette | |||||
Optical System | Light Source | 12V/30W halogen-tungsten lamp, 2000 hours | ||||
Receiver | 8 precision photo receivers | |||||
Wavelength Range | 340,405,450,510,546,578,630,700mm | |||||
Calibration and QC | Calibration | one-point,multi-point | Linear Range | 0.000~2.500Abs | ||
Quality Control | Inserting quality control at random. | |||||
Software |
Emergency Function | emergency sample can be arranged at any time | ||||
Software | Windows XP or 7, sample and easy to operate | |||||
Data Processing | Having reaction curve detection and data display function in whole process. | |||||
Others | Power Supply | AC220V+22V/50Hz+1Hz | ||||
Dimension | 1070mm×910mm×1230mm (W*D*H) | |||||
Weight | 180kg |
Suppliers with verified business licenses