• Biobase Ce Certificated Multi-Channel Micropipette Lab Pipette
  • Biobase Ce Certificated Multi-Channel Micropipette Lab Pipette
  • Biobase Ce Certificated Multi-Channel Micropipette Lab Pipette
  • Biobase Ce Certificated Multi-Channel Micropipette Lab Pipette

Biobase Ce Certificated Multi-Channel Micropipette Lab Pipette

Customized: Non-Customized
Structure: Desktop
Material: Plastic
Certification: CE, ISO, RoHS
Application: School, Hospital, Lab
Type: Separation Type
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Shandong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)

Basic Info.

Model NO.
Multi-Channel Micropipette
Range
30-300UL
Channel Pipettes
8-12
Standard Plate
96-Well
Chanles
Single,6,8,12
Transport Package
Standard Packaging
Specification
CE SGS
Trademark
BIOBASE
Origin
China
Production Capacity
Piece

Product Description


DESCRIPTIONS
*Individual piston and tip cone assemblies
allow easy repair and maintenance
*Compound material tip cone design
allows visual seal verification
*Can be used with universal style pipette
tips

FEATURES:

Model:712112120000
*8 and 12 channel pipettes are available
for standard 96-well plate
*Dispensing head rotates for optimum
pipetting convenience
*Individual piston and tip cone assemblies
allow easy repair and maintenance
*Compound material tip cone design
allows visual seal verification
*Can be used with universal style pipette
tips

SPECIFICATIONS
*Color coded button
*Precise volume adjustment &
light pipetting forces
*Easy tip ejection
*One hand volume adjustment
*Highly resistant materials
*Convenient auto-clavable lower parts
*Easy tip-ejector removal
*Easy lower part rotation
*Range 30-300ul
SPECIFICATIONS

MicroPette  Single-Channel Adjustable Volume Pipettes
Model Volume Range  Increment Test Volume(μl) Maximume Permissible
Systematic error 
(Inaccuracy)
Maximume Permissible 
Random error 
(Inaccuracy)
        % μl % μl
71211010000 0.1-2.5μl 0.05μl 2.5 2.50% 0.0625 2.00% 0.05
1.25 3.00% 0.0375 3.00% 0.0375
0.25 12.00% 0.03 6.00% 0.015
71211040000 0.5-10μl 0.1μl 10 1.00% 0.1 0.80% 0.08
5 1.50% 0.075 1.50% 0.075
1 2.50% 0.025 1.50% 0.015
71211050000 2-20μl 0.5μl 20 0.90% 0.18 0.40% 0.08
10 1.20% 0.12 1.00% 0.1
2 3.00% 0.06 2.00% 0.04
71211060000 5-50μl 0.5μl 50 0.60% 0.3 0.30% 0.15
25 0.90% 0.225 0.60% 0.15
5 2.00% 0.1 2.00% 0.1
71211080000 10-100μl 1μl 100 0.80% 0.8 0.15% 0.15
50 1.00% 0.5 0.40% 0.2
10 3.00% 0.3 1.50% 0.15
71211090000 20-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
20 3.00% 0.6 1.00% 0.2
71211110000 50-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
50 1.00% 0.5 0.40% 0.2
71211140000 100-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
100 2.00% 2 0.70% 0.7
71211160000 200-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
200 0.90% 1.8 0.30% 0.6
71211170000 1000-5000μl 50μl 5000 0.50% 25 0.15% 7.5
2500 0.60% 15 0.30% 7.5
1000 0.70% 7 0.30% 3
71211330000 2-10ml 0.1ml 10ml 0.60% 60 0.20% 20
5ml 1.20% 60 0.30% 15
2ml 3.00% 60 0.60% 12
 8-channel Adjustable Volume Pipettes
Model Volume Range Increment Test Volume(μl) Maximume Permissible 
Systematic error 
(Inaccuracy)
Maximume Permissible 
Random error 
(Inaccuracy)
        % μl % μl
71212040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4.00% 0.04 4.00% 0.04
71212060000 5-50μl 0.5μl 50 1.00% 0.5 0.50% 0.25
25 1.50% 0.375 1.00% 0.25
5 3.00% 0.15 2.00% 0.1
71212120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1.00% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
12-channel Adjustable Volume Pipettes
Model Volume Range Increment Test Volume
(μl)
Maximume Permissible 
Systematic error 
(Inaccuracy)
Maximume Permissible 
Random error 
(Inaccuracy)
        % μl % μl
71213040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4.00% 0.04 4.00% 0.04
71213060000 5-50μl 0.5μl 50 1.00% 0.5 0.50% 0.25
25 1.50% 0.375 1.00% 0.25
5 3.00% 0.15 2.00% 0.1
71213120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1.00% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
 Fixed Volume Pipettes
Model Volume Range Increment Test Volume Maximume Permissible 
Systematic error 
(Inaccuracy)
Maximume Permissible 
Random error 
(Inaccuracy)
        % μl % μl
71221180000 5μl - 5μl 1.3% 0.065 1.2% 0.06
71221190000 10μl - 10μl 0.8% 0.08 0.8% 0.08
71221200000 20μl - 20μl 0.6% 0.12 0.5% 0.1
71221210000 25μl - 25μl 0.5% 0.125 0.3% 0.075
71221220000 50μl - 50μl 0.5% 0.25 0.3% 0.15
71221230000 100μl - 100μl 0.5% 0.5 0.3% 0.3
71221240000 200μl - 200μl 0.4% 0.8 0.2% 0.4
71221250000 250μl -- 250μl 0.4% 1.0 0.2% 0.5
71221260000 500μl - 500μl 0.3% 1.5 0.2% 1.0
71221270000 1000μl - 1000μl 0.3% 3.0 0.2% 2.0
71221280000 2000μl - 2000μl 0.3% 6.0 0.15% 3.0
71221290000 5000μl - 5000μl 0.3% 15 0.15% 7.5