Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 14/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Single-channel Adjustable Volume Pipettes |
||||||
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||
% |
μl |
% |
μl |
|||
0.1-2.5μl |
0.05μl |
2.5 |
2.50% |
0.0625 |
2.00% |
0.05 |
1.25 |
3.00% |
0.0375 |
3.00% |
0.0375 |
||
0.25 |
12.00% |
0.03 |
6.00% |
0.015 |
||
0.5-10μl |
0.1μl |
10 |
1.00% |
0.1 |
0.80% |
0.08 |
5 |
1.50% |
0.075 |
1.50% |
0.075 |
||
1 |
2.50% |
0.025 |
1.50% |
0.015 |
||
2-20μl |
0.5μl |
20 |
0.90% |
0.18 |
0.40% |
0.08 |
10 |
1.20% |
0.12 |
1.00% |
0.1 |
||
2 |
3.00% |
0.06 |
2.00% |
0.04 |
||
5-50μl |
0.5μl |
50 |
0.60% |
0.3 |
0.30% |
0.15 |
25 |
0.90% |
0.225 |
0.60% |
0.15 |
||
5 |
2.00% |
0.1 |
2.00% |
0.1 |
||
10-100μl |
1μl |
100 |
0.80% |
0.8 |
0.15% |
0.15 |
50 |
1.00% |
0.5 |
0.40% |
0.2 |
||
10 |
3.00% |
0.3 |
1.50% |
0.15 |
||
20-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
100 |
0.80% |
0.8 |
0.30% |
0.3 |
||
20 |
3.00% |
0.6 |
1.00% |
0.2 |
||
50-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
100 |
0.80% |
0.8 |
0.30% |
0.3 |
||
50 |
1.00% |
0.5 |
0.40% |
0.2 |
||
100-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
500 |
0.70% |
3.5 |
0.25% |
1.25 |
||
100 |
2.00% |
2 |
0.70% |
0.7 |
||
200-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
500 |
0.70% |
3.5 |
0.25% |
1.25 |
||
200 |
0.90% |
1.8 |
0.30% |
0.6 |
||
1000-5000μl |
50μl |
5000 |
0.50% |
25 |
0.15% |
7.5 |
2500 |
0.60% |
15 |
0.30% |
7.5 |
||
1000 |
0.70% |
7 |
0.30% |
3 |
||
2-10ml |
0.1ml |
10ml |
0.60% |
60 |
0.20% |
20 |
5ml |
1.20% |
60 |
0.30% |
15 |
||
2ml |
3.00% |
60 |
0.60% |
12 |
8-channel Adjustable Volume Pipettes |
||||||||
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||||
% |
μl |
% |
μl |
|||||
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
||
5 |
2.50% |
0.125 |
2.50% |
0.125 |
||||
1 |
4.00% |
0.04 |
4.00% |
0.04 |
||||
5-50μl |
0.5μl |
50 |
1.00% |
0.5 |
0.50% |
0.25 |
||
25 |
1.50% |
0.375 |
1.00% |
0.25 |
||||
5 |
3.00% |
0.15 |
2.00% |
0.1 |
||||
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
||
150 |
1.00% |
1.5 |
0.50% |
0.75 |
||||
50 |
1.50% |
0.75 |
0.80% |
0.4 |
||||
12-channel Adjustable Volume Pipettes |
||||||||
Volume Range |
Increment |
Test Volume (μl) |
Maximume Permissible Systematic error (Inaccuracy) |
Maximume Permissible Random error (Inaccuracy) |
||||
% |
μl |
% |
μl |
|||||
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
||
5 |
2.50% |
0.125 |
2.50% |
0.125 |
||||
1 |
4.00% |
0.04 |
4.00% |
0.04 |
||||
5-50μl |
0.5μl |
50 |
1.00% |
0.5 |
0.50% |
0.25 |
||
25 |
1.50% |
0.375 |
1.00% |
0.25 |
||||
5 |
3.00% |
0.15 |
2.00% |
0.1 |
||||
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
||
150 |
1.00% |
1.5 |
0.50% |
0.75 |
||||
50 |
1.50% |
0.75 |
0.80% |
0.4 |
Factory Views:
Founded in 1999, BIOBASE Group having over 2000 employees (till August, 2018), BIOBASE Group is a new high-tech enterprise focusing on development, production and management of scientific equipment, In Vitro Diagnosis (IVD) instrument and reagent.