Biobase Class II B 2 Biological Safety Cabinet

Product Details
Customization: Available
Material: Stainless Steel
Type: Heap Filter
Still deciding? Get samples of US$ 2600/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • Biobase Class II B 2 Biological Safety Cabinet
  • Biobase Class II B 2 Biological Safety Cabinet
  • Biobase Class II B 2 Biological Safety Cabinet
  • Biobase Class II B 2 Biological Safety Cabinet
  • Biobase Class II B 2 Biological Safety Cabinet
  • Biobase Class II B 2 Biological Safety Cabinet
Find Similar Products

Basic Info.

Model NO.
BSC-1100IIB2-X
Usage
Hospital, Company, Research Institute
Color
Blue
Customized
Customized
Condition
New
Gross Weight
246kg
Internal Size (W*D*H)
940*600*660 mm
External Size (W*D*H)
1100*750*2250mm
Tested Opening
Safety Height 200 mm(8′′)
Max Opening
420mm(17′′)
Pre-Filter
Washable
UV Lamp
30W*1
Transport Package
Standard Export Package
Specification
1100**750*2250mm
Trademark
BIOBASE
Origin
China
Production Capacity
1000000/Month

Product Description

Class II B 2 Biological Safety Cabinet

 
Details Image

Application

Three protection: operator, sample and environment.

Airflow system: 0 % air recirculation, 100% air exhaust
A Class II B2 BSC, also called a total exhaust cabinet, is necessary when significant amounts of radionuclides and volatile chemicals are expected to be used.

 

Advantage: 

1. Time reserve function.
2. Motorized front window.
3. HEPA filter life and UV life indicator.
4. Automatic air speed adjustable with filter block.
5. With memory function in case of power-failure.
6. Work area surrounded by negative pressure, it can ensure maximum safety in work area.
7. Most accessories are standard, which saves your money. There is no need to pay more.
8. Audio and visual alarm (filter replacement, window over height, abnormal air flow velocity, etc).
9. Remote control. All functions can be realized with it, making the operation much easier and more convenient.
10. Interlock function: UV lamp and front window; UV lamp and blower, fluorescent lamp; blower and front window.

11. Foot switch. Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement.


Biobase Class II B 2 Biological Safety Cabinet
Biobase Class II B 2 Biological Safety Cabinet


Parameters:
 

Model

BSC-1100IIB2-X

BSC-1300IIB2-X

BSC-1500IIB2-X

BSC-1800IIB2-X

Internal Size

(W*D*H)

940*600*660 mm

1150*600*660 mm

1350*600*660mm

1700*600*660 mm

External Size

(W*D*H)

1100*750*2250mm

1300*750*2250mm

1500*760*2250mm

1873*775*2270mm

Tested Opening

Safety Height 200 mm(8'')

Max Opening

420mm(17'')

420mm(17'')

500mm(20'')

480mm(20'')

Inflow Velocity

0.53±0.025 m/s

Down flow Velocity

0.33±0.025 m/s

Pre-Filter

Washable

HEPA Filter

Two, 99.999% efficiency at 0.3 μm,filter life indicator.

Front Window

Motorized,two-layer laminated toughened glass ≥ 5mm,anti UV.

Noise

NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB 

UV Lamp

30W*1

30W* 1

40W* 1

40W*1

UV timer, UV life indicator, emission of 253.7 nanometers 

for most efficient decontamination.

Illuminating Lamp

LED Lamp

LED Lamp

LED Lamp

LED Lamp

12W*2

14W*2

16W*2

16W*2

Illumination

≥1000Lux

Consumption

700W

850W

900W

1200W

Waterproof Sockets

Two, total load of two sockets: 500W

Display

LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, 

inflow and downflow velocity, filter life, humidity and temperature, system working time etc.

Control System

Microprocessor

Airflow System

0% air recirculation, 100% air exhaust

Alarm

Abnormal airflow velocity; Filter replacement; Front window at unsafe height.

Exhaust Duct

4 meters PVC duct, Diameter:300mm

Material

Work Zone: 304 stainless steel

Main Body: Cold-rolled steel with anti-bacteria powder coating.

Work Surface Height

750mm

Caster

Foot master caster

Power Supply

AC 220V±10%, 50/60Hz; 110V±10%, 60Hz (110V/60Hz is not applicable to BSC-1800IIB2-X)

Standard Accessory

Illuminating lamp, UV lamp*2,base stand, remote control, foot switch, exhaust blower, 

exhaust duct, drain valve, waterproof sockets*2, pipe strap*2

Optional Accessory

Water and gas tap, Electric height adjustable base stand

Gross Weight

246kg

276kg

302kg

408kg

Package

Main Body

1230* 990* 1810 mm

1460*1050*1800 mm

1650*990*1810 mm

2000*950*1820 mm

Exhaust Blower (W*D*H)

970* 810* 630 mm

970* 810* 630 mm

970* 810* 630 mm

970* 810* 680 mm




Why Choose Us:

Biobase Class II B 2 Biological Safety Cabinet
Biobase Class II B 2 Biological Safety Cabinet
Biobase Class II B 2 Biological Safety Cabinet

*Founded in 1999, having over 2000 employees.

*BIOBASE Group is specialized in products of 8 areas including medical diagnosis, biosafety protection, disinfection and sterilization, water purification system, infant care products, cold chain products, software products, clean room project.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More