Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

Product Details
Customization: Available
After-sales Service: 24 Hour Online Technical Support
Application: Laboratory Apparatus
Still deciding? Get samples of US$ 6699/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
  • Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
Find Similar Products
  • Overview
  • Features
  • Technical Parameters
  • Company Profile
  • Contact Us
Overview

Basic Info.

Model NO.
BK-AA320N
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
New Spectrometer
Wavelengths
Atomic Absorption Spertrophotometer
Customized
Customized
Product Name
Atomic Absorption Spectrophotometer
Model
Bk-AA320n
Wavelength Range
190~900nm
Wavelength Accuracy
0.5nm
Wavelength Repeatability
0.3nm (Single Direction)
Spectral Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Grating
1800 Lines/mm
Resolution
40%
Base Line Stability
0.004ABS/30min
Characteristic Concentration
0.04μg/Ml/1% (Cu)
Detection Limit
0.008μg/Ml (Cu)
Background Calibration
30 Times
Power Supply.
220V, 50/60Hz
Packing Size(mm)
1250*795*765 (Main Instrument) 545*445*1385 ( a
Gross Weight(Kg)
138kg (Main Instrument) 56kg ( Accessories )
Transport Package
Standard Package
Specification
1250*795*765
Trademark
BIOBASE
Origin
China
Production Capacity
1000 Units Per Month

Product Description

Biobase Atomic Absorption Spertrophotometer Industrial Spectrometer

Features
 
Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
Features:
 

* Build-in computer data processing and LCD display.

* Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.

* Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
* High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.

* High energy optical path.

* Long-life and anti-corrosive atomization system.

* Multi-functional analysis mode: ?flame absorption?flame emission? graphite furnace atomic absorption  hydride generation.

* Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.



Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
Technical Parameters

Model

BK-AA320N

Wavelength Range

190~900nm

Wavelength Accuracy

≤±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Grating

1800 lines/mm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration

≤ 0.04μg/ml/1% (Cu)

Detection Limit

≤0.008μg/ml (Cu)

Background Calibration

>30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250*795*765 (Main instrument)

545*445*1385 ( Accessories )

Gross Weight(kg)

138Kg (Main instrument)

56Kg ( Accessories )

Standard Accessories

RS232 serial port

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit, Burner unit ,Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories

Model GA3202 HGA graphite furnace system

Hydride generator

Graphite tubes

Recirculating cooling water system

Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

Company Profile

 

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal AnalysisFactory Views:
Founded in 1999, BIOBASE Group having over 2000 employees (till August, 2018), BIOBASE Group is a new high-tech enterprise focusing on development, production and management of scientific equipment, In Vitro Diagnosis (IVD) instrument and reagent.

 
BIOBASE Group is specialized in products of 8 areas including medical diagnosis, biosafety protection, disinfection and sterilization, water purification system, infant care products, cold chain products, software products, clean room project.

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis
Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

 
Contact Us

 

Biobase Industrial Spectrometer Atomic Absorption Spertrophotometer for Metal Analysis

 



 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More