• Biobase Bk-Gc112A High Performance Gas Chromatograph

Biobase Bk-Gc112A High Performance Gas Chromatograph

Appliance: The Analysis of Environmental Samples
Ray Type: Gamma Ray Spectrometer
Gaspath System: Double
Detector: FID
Energy Resolution: ≤7.5%
Certification: CE, ISO
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
BK-GC112A
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Temperature Control Range
Rt+5 Degree~400 Degree
Temperature Accuracy
+-0.02 Degree
Temp. Program
9-Phase/ 10 Platform
Max Temp. Heating Rate
60 Degree/Min
Sample Injector
Column or Split Injector Can Be Installed
Split Mode
Can Directly Set The Split Ratio
Detection Limit
<=3*10-12g/S (Sample: N-Hexadecane)
Dynamic Range
107
Package Size (W*D*H)
1020*660*740mm
Gross Weight
82kg
Transport Package
Carton, Wooden
Specification
ISO
Trademark
BIOBASE
Origin
China
Production Capacity
2000units

Product Description

BK-GC112A Gas Chromatograph

Features:
7-inch LCD display indicates temperature, gas flow and heating curve.Self-test function and automatic fault recognition function.8 pcs external extension interfaces can connect with control valve.Equipped with a flame ionization detector (FID) which adopts APC control.Multi-core and 32-bit embedded hardware system ensures the reliable operation.Synchronous external trigger function and the external signal (auto sampler, hot analytical instruments, etc.) can start the equipment and workstation software at the same time.With chromatography workstation software to process data.
Technical Parameter:
ModelBK-GC112A
OvenTemp. RangeRT+5ºC~400ºC
Temp. Accuracy±0.02ºC
Temp. Program9-phase/ 10 platform
Max Temp. Heating Rate60ºC/min
Sample InjectorTemp. RangeRT+7ºC~420ºC
Column or split injector can be installed.
Split mode can directly set the split ratio.
Constant pressure mode.
A separate injection system is connected.
DetectorTemp. RangeRT+7ºC~420ºC
Hydrogen Flame Ionization Detector (FID)Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3*10-12g/s
(Sample: n-hexadecane)
Dynamic range: 107
Thermal Conductivity Detector (TCD)
(Optional)
Bridge voltage switch control
Bridge current setting: 0-220mA
Sensitivity: 6000mv.ml/mg
Dynamic range: 105
Power SupplyAC220V±10%, 50/60Hz
Standard AccessoryFID detector, Capillary injection system, Chromatography workstation software.
Optional AccessoryTCD detector, Chromatographic column, Gas purifier.
Package Size (W*D*H)1020*660*740mm
Gross Weight82kg

Send your message to this supplier

*From:
*To:
avatar Ms. Anna
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
730
Year of Establishment
2007-07-18