Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Still deciding? Get samples of US$ 6799/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
  • Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
  • After Sales Service
  • Related Products
  • Contact us
Overview

Basic Info.

Model NO.
BK-GS6060
Appliance
The Analysis of Environmental Samples
Optical Geometry
Reflect: Di:8°, De:8°
Integrating Sphere Size
Φ154mm
Light Source
360 Nm to 780 Nm
Spectrophotometric Mode
Concave Grating
Sensor
256 Image Element Double Array CMOS Image Sensor
Wavelength Range
360-780nm
Wavelength Interval
10nm
Semi-Band Width
10nm
Measured Reflectance Range
0-200%
Specular Component
Reflectance: Sci&Sce / Transmittance: Sci&Sce
Observer Angle
2°/10°
Measuring Time
About 2.4s
Illuminant Life Span
5 Years
Display
7-Inch TFT Color LCD
Transport Package
Cartoon Package or Wooden
Specification
BK-GS6060
Trademark
BIOBASE
Origin
China
Production Capacity
1000 PCS Per Year

Product Description

BIOBASE Benchtop Grating Spectrophotometer Color Analysis
Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer
Product Description

 

BK-GS6060 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely
applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical,
cosmetics, food, science institutes, laboratories.
 

Features:

 
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch screen
Display; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED and xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color
transmission.
4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm ~780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users' requirement.
9.Multiple accessories, sample holders, fixation clamp, suitable to more working condition.
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Product Parameters
Model
BK-GS6060
Optical Geometry
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Application
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and
dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size
Φ154mm
Light Source
360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm Cut-off light source, UV Lamp
Spectrophotometric Mode
Concave Grating
Sensor
256 Image Element Double Array CMOS Image Sensor
Wavelength Range
360-780nm
Wavelength Interval
10nm
Semi-band Width
10nm
Measured Reflectance Range
0-200%
Measuring Aperture
Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm;
Specular Component
Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space
CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN
Color Difference Formula
ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric Index
WI (ASTM E313, CIE/ISO, AATCC, Hunter,
YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO),
MI (Metamerism Index), Staining Fastness,
Color Fastness, Color Strength, Opacity,
Gardner Index, Pt-Co Index, 555 Index
Observer Angle
2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time
About 2.4s (Measure SCI & SCE about 5s)
Repeatability
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5
second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm:
within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5
second intervals after white calibration)
Inter-instrument Error
Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles)
Illuminant Life Span
5 years, more than 3 million times measurements
Display
7-inch TFT color LCD, Capacitive Touch Screen
Data Port
USB & Bluetooth
Data Storage
Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE)
Language
Chinese, English
Operating Environment
0~40ºC, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment
-20~50ºC, 0~85%RH (no condensing)
Standard Accessory
White and Black Calibration Board, Checking Green Board, Sample Holder,∮4mm, ∮8mm, ∮15mm, ∮25.4mm Aperture, Power Adapter, USB
Cable, User Guide, PC Software
Optional Accessory
Micro printer, Transmissive Test Clamp Component
Power Supply
DC 24V, 3A; Power adapter: 110~230V 50/60HZ
External Size(L*W*H)
370*300*200mm
Weight
9.6kg
Package Size (W* D*H)
350*470*520mm
Gross Weight
18kg
Packaging & Shipping

Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

Company Profile

Biobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

Our Advantages

Biobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

After Sales Service

Biobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

Related Products

Biobase Auto Identify Measuring Aperture Benchtop Grating SpectrophotometerBiobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

Contact us

Biobase Auto Identify Measuring Aperture Benchtop Grating Spectrophotometer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More