• Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
  • Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
  • Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
  • Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
  • Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
  • Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

After-sales Service: 24 Hour Online Technical Support
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Balancing Machine
Maxcapacity: <1000KN
Samples:
US$ 5090/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Shandong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)
  • Overview
  • Features
  • Product Parameters
  • Packaging & Shipping
  • <span style="display:inline-block;"><span style="display:inline-block;"><span cke-mic-navigation-content="" style="border-radius:3px;padding:0 10px;display:inline-block;line-height:36px;text-align:left;">Company Profile</span></span></span>
  • Exhibition
  • Big Project
  • After Sales Service
Overview

Basic Info.

Model NO.
BK-FP261D
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Model
Bk-Fp261
Ambient Temperature
≤ 35ºC
Relative Humidity
≤85%
Consumption
650W
Flash Point Determination
Mercury-in-Glass Thermometer.Specifications Are as
Heating Device
The Heating Power Is Continuously Adjustable From
Heating Rate
(1~12)ºC/Min; Controllable and Adjustable
Dimension(W*D*H)
340*320*450mm
Gross Weight
12.5kg
Model2
Bk-Fp261d
Ambient Temperature2
15~35°c
Relative Humidity 2
≤85%
Stirring Rate2
Procedure a:(90~120)Rpm, Procedure B: (250)Rpm
Consumption2
≤600W
Power Supply
AC220V±10%, 50Hz
Transport Package
Standard Export Package
Specification
470*400*410mm
Trademark
Biobase
Origin
China
Production Capacity
5000/Month

Product Description

Biobase Closed Flash Point And Fire Point Tester Apparatus

 
Features
Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface


Features:
 

It is used to make determination of the closed cup flash point of the petroleum products.

 

 

 

 

 

Features:

BK-FP261:

The heating power is adjustable and shown visually by voltmeter.

The structure is designed small and exquisite with stainless-steel table board.

BK-FP261D:

*8-inch IPS high-definition capacitive screen, the test data and parameters are displayed by curve in real time.

Equipped with Bluetooth interface. The user can query test data anytime.

Temperature rise, cover opening, ignition, detection and printing data are completed automatically, and the test arm rises and falls automatically.

Remote automatic upgrade to obtain the latest version, remote prediction, abnormal early warning, comprehensive evaluation and maintenance of instrument operation status.

Electronic ignition, gas flame, automatic air cooling at the end of the test.

Product Parameters
 

Model

BK-FP261

BK-FP261D

Ambient Temperature

15~35°C

Relative Humidity

≤85%

Flash Point Determination

Mercury-in-glass thermometer. Specifications are as below: Scale -5°C~110°C, division 0.5°C Scale 20°C~150°C, division 1°C Scale 90°C~370°C, division 2°C

Range: Ambient to 230°C Repeatability:3°C Reproducibility: 4°C Accuracy: 0.1 °C

Oil Cup

Inner diameter: 50.7mm~50.8mm.

Depth: 55.7mm~56.0mm

The scribed line depth of capacity of testing oil: 33.9mm-34.3mm. Capacity of testing oikabout 70ml

Stirring Rate

Procedure A: (90~120)RPM, Procedure B: (250±10)RPM

Igniting Device

Igniting source: gas(or other civilian fuels, the same below)

Electric ignition.

Diameter of igniter: 0.7mm~0.8mm

Heating Device

The heating power is continuously adjustable from 0 Wto 600W.

Heating Rate

(1~12)°C/min: Controllable and adjustable

Procedure A: (5-6)°C/min, Procedure B: (1~1.5)°C/min, Procedure C:(3±0.5) °C/min

Consumption

M650W

600W

Power Supply

AC220V±10%, 50Hz

Dimension(W*D*H)

370*320*300mm

510*320*330mm

Package Size(W*D*H)

460*400*410mm

690*500*600mm

Gross Weight

13kg

33kg

Packaging & Shipping

 

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

Company Profile
 

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

Factory Views:
Founded in 1999, BIOBASE Group having over 2000 employees (till August, 2018), BIOBASE Group is a new high-tech enterprise focusing on development, production and management of scientific equipment, In Vitro Diagnosis (IVD) instrument and reagent.

 
BIOBASE Group is specialized in products of 8 areas including medical diagnosis, biosafety protection, disinfection and sterilization, water purification system, infant care products, cold chain products, software products, clean room project.

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
 

Exhibition
 
 
Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
Big Project
Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth InterfaceBiobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth InterfaceBiobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface

 

After Sales Service

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth InterfaceBiobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface
 

Biobase Closed-Cup Flash Point Meter Petrol Analysis Testing with Bluetooth Interface


 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now