• Biobase Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with Ce Certification
  • Biobase Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with Ce Certification

Biobase Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with Ce Certification

Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Wavelengths: Visible Spectrometer
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Shandong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 36 foreign trading staff(s) and 33 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (34)

Basic Info.

Model NO.
BK-D560/BK-D580/BK-D590
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Non-Customized
Optical System
Double Beam, Grating 1200 Lines/Mm
Wavelength Range
190-1100nm
Spectral Bandwidth
4nm
Wavelength Accuracy
0.3nm
Wavelength Repeatability
0.2nm
Stray Light
≤ 0.1 % T @ 360nm; 220nm(0.2)
Display
128*64 Dots LCD
Photometric Mode
T, a, C, E
Photometric Range
0-200%T, -0.301-3.0A
Output
USB2.0*2 Print and Data Output USB1.0 Connect PC
Transport Package
Carton
Specification
ISO, CE
Trademark
BIOBASE
Origin
China
HS Code
902730000
Production Capacity
1000sets Per Months

Product Description

Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with CE certification
Biobase Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with Ce Certification
Application

Spectrophotometers are widely used for Organic chemistry,
Inorganic chemistry,Life sciences,foods, Medicine and health,
Agriculture,Geology,Metallurgy and Environment etc.fields.



Features:
Large LCD screen(480*800) with 65 thousand true color and support U disk data saving
Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
 Data output: Data can be exported to U disk (USB Output)
Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
 Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
Pre-aligned design ensures the user can change lamps conveniently
With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off protection
Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
With Si02 coating optical mirror, reducing the pollution from outside fully
 
Basic Functions:
 1, Photometry
  Test Abs., Transmittance and Energy by fixed
  wavelength 
2, Quantitative
   Linear fit and Linear fit through zero two modes
 a.Coefficient, Standard Sample input and Standard
 Sample read three modes to establish standard curve    
 b. Establish A=K1*C+K0, can search original data, graph
   curve, parameters settings  
 c. Can save 240 group curves, can test 240 data in each
  curve 
 d. Double wavelength, Triple wavelength test functions.
3, Kinetics
Used for time course scanning or reaction rate
calculationsA/t, can search all data 
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different
wavelengths at most
5, Scanning
   User can set the scan range from 190nm to 
   1100nm to test the max. Abs. peak value, can do 
   derivation, arithmetical operations to the graph.
6, Biology
   6 methods: DNA/Protein, UV, Lowry, BCA,CBB 
   and Biuret

Parameters
 

Model

BK-D560

BK-D580

BK-D590

Optical System

Double Beam, Grating 1200 lines/mm

Wavelength Range

190-1100nm

Wavelength Range

1.8nm

1nm

0.5,1,2,4,5nm

Wavelength Accuracy

± 0.3nm

Wavelength Repeatability

≤ 0.2nm

Photometric Accuracy

± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.3% T (0-100% T) (0.3, 0.003)

Photometric Repeatability

0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs), ≤ 0.2% T (0-100% T)

Stray Light

≤ 0.03 T @ 360nm; 220nm(0.04)

Stability

± 0.0003A / h @ 500nm

Baseline Flatness

± 0.0005A

Noise

± 0.0002Abs

Display

65 thousand true color 7 inch TFT LCD(480 *800)

Photometric Mode

T, A, C, E

Photometric Range

0-200% T,-0.301-3.0A

Detector

Silicon Photodiode

Light Source

Deuterium Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

USB2.0*2 Print and data output  USB1.0 Connect PC

Compartment

Optional 8 Auto Cell holder, Solid Sample Holder, Micro Cell Holder, 10-100mm Cell Holder

Biobase Advantage:
1.Established in 1999,owning more than 1300 employees & 20000 square meters production base and 22.4 acres industry park, amount to 10000 units yearly output.
2.16 years production experience &100 professional engineers.
3.Third party strong quality control team and technical production.
4.Certified by NSF49, EN12469, CE, ISO13485, ISO14001, ISO9001, SFDA,TUV, SGS, FDA, MET.
5.Superior quality & competitive price are guaranteed.
6.At least 10 international affairs attend yearly: American FIME&Pittcon,AACC exhibition,Russia Zdravook hraneniye, Arab health&Lab, Germany Analytica&Media,Brazil Hospitalar,India Lab expo&Medical fair,Lab Indonesia, Medical Myanmar,Analytica Vietnam,Lab Asia,etc.
Biobase Double Beam Scanning UV/Vis Spectrophotometer / Spectrometer with Ce Certification

BIOBASE is your best choice!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now